Horizontal FRP storage tank and vertical FRP storage tank installation method

2024-7-15

Storage tank is used to store liquid or gas sealed container, glass fiber reinforced plastic storage tank according to the shape can be divided into horizontal and vertical two, vertical glass fiber reinforced plastic storage tank occupies a small area, discharge is convenient and fast, horizontal glass fiber reinforced plastic storage tank volume is small, but easy to handle, the following to understand the installation method of these two glass fiber reinforced plastic storage tanks.

[Installation method of FRP horizontal storage tank]

The saddle supports of 2α=180° must be consistent with the outer wall of the FRP tank. The supports must be placed separately according to the designed supporting positions, and the FRP tank can be placed after being completely straightened and levelled. A 4-6mm rubber pad should be placed between the supports and the container. Before falling into the tank, a layer of fine sand cement can be applied on the entire support surface, and a layer of rubber sheet can be laid on the unset cement. Then, the tank can be dropped, the excess cement can be extruded, and the fit can be filled.

[Installation method of glass fiber Reinforced plastic vertical storage tank]

1. Sand cushion: Lay a layer of building fine sand on the concrete foundation, the sand does not contain stones greater than 5mm, in principle, the center is thick and the surrounding is thin, and the thickness of the surrounding sand layer is 30-50mm.

2, drop the can: according to the lifting requirements, carefully drop the FRP can on the sand layer, do not remove the hook after dropping the can, in order to repeatedly lift the sand before the cushion.

3, inspection: check whether there is leakage in the tank.

4, do sand tank: In order to prevent the fine sand around the bottom edge from being washed away by rain or overflow, it must be built or poured according to the requirements of the sand tank, after the tank solidified, filled with fine sand and rammed.

5. Asphalt sealing tank: Use asphalt or asphalt mortar to irrigate the upper mouth of the closed sand retaining tank to prevent water and sand loss in the tank.

The above is the introduction of the horizontal and vertical FRP storage tank installation method, in actual use, we should also pay attention to the horizontal FRP storage tank than the vertical FRP storage tank thickness is different, horizontal FRP storage tank is made of uniform interference, the thickness in addition to reinforcement, basically the same; The vertical FRP storage tank is generally the upper tank is slightly thinner than the lower tank